iTEMP® HART® TMT182
Temperature head transmitter
Head transmitter for resistance thermometers (RTD),
thermocouples (TC), resistance and voltage transmitters (mV),
HART® -protocol, for installation in a sensor head Form B
Application
• Temperature head transmitter with HART® -protocol for converting various input signals into an scalable 4 to 20 mA analogue output signal
• Input:
Resistance thermometer (RTD)
Thermocouple (TC)
Resistance transmitter (Ω)
Voltage transmitter (mV)
• HART® -protocol for front end unit or panel unit operation using the hand operating module (DXR275, DXR375) or PC
(e. g. ReadWin® 2000, COMMUWIN II or FieldCare)
• Ex-Certification
- ATEX Ex ia and dust zone 22 in
compliance with EN 50281-1
- FM IS
- CSA IS
• Galvanic isolation
• Output simulation
• Min./max. process value indicator function
• Customer specific linearization
• Linearization curve match
• Customer specific measurement range settings or expanded SETUP
Your benefits
• Universal settings with HART® -protocol for various input signals
• Operation, visualisation and maintenance via PC,
e. g. COMMUWIN II operating software
• 2 wire technology, 4 to 20 mA analogue output
• High accuracy in total ambient temperature range
• Fault signal on sensor break or short circuit, presettable to NAMUR NE 43
• EMC to NAMUR NE 21, CE
• UL recognized component to UL 3111-1
• GL Germanischer Lloyd marine approval
Measuring system:
The iTEMP® HART® TMT182 temperature head transmitter is a two wire transmitter with analogue output. It has measurement input for resistance thermometers (RTD) in 2-, 3- or 4-wire connection, thermocouples and voltage transmitters. Setting up of the TMT182 is done using the HART® -Protocol with hand operating module (DXR275, DXR375) or PC (COMMUWIN II).