Add to Cart
Endress+Hauser CCPS32 Capacitive Ceramic Pressure Sensor
- Extremely high overload limit
- Absolutely resistant to wear
- High temperature stability
- High long-term stability
- No hysteresis
- Corrosion-resistant
Input | |
MeasuringrangesGaugepressure | |
Gaugepressureranges | Max.permissibleoverload |
-2.5......2.5Kpa | 250Kpa |
0......5Kpa | -30Kpa/400Kpa |
0......10Kpa | -30Kpa/400Kpa |
-10......10Kpa | 600Kpa |
0......20Kpa | 600Kpa |
-20......20Kpa | 600Kpa |
0......40Kpa | 600Kpa |
0......100Kpa | 1Mpa |
-40......100Kpa | 1Mpa |
-100......100Kpa | 1Mpa |
0......200Kpa | 1.8Mpa |
-100......400Kpa | 2.5Mpa |
-0.1......1Mpa | 4Mpa |
-0.1......2Mpa | 4Mpa |
-0.1......4Mpa | 6Mpa |
-0.1......7Mpa | 10.5Mpa |
Output | |||
Outputsignal | 0.5V...4.5V | ||
Zero | 0.50V±0.05V | ||
Range | 4.50V±0.05V | ||
Hysteresis | negligible | ||
Characteristics | Linear | ||
Conformity(sumoflinearityerror, | ≤0.2%ofoutputrange | ||
hysteresisandrepeatability) | |||
Permissibleload | ≥10KΩ≥300pF | ||
Risetime | Approx.1ms | ||
Switch-ontime | Max.10ms | ||
Long-termstability | Max.annualerror0.1%ofrange | ||
Absolutepressure | |||
Absolutepressureranges | Max.permissibleoverload | ||
0......10Kpa | 400Kpa | ||
0......20Kpa | 600Kpa | ||
0......100Kpa | 1Mpa | ||
0......120Kpa | 1Mpa | ||
0......200Kpa | 1.8Mpa | ||
0......400Kpa | 2.5Mpa | ||
0......500Kpa | 2.5Mpa | ||
0......1Mpa | 4Mpa | ||
0......2Mpa | 4Mpa | ||
0......4Mpa | 6Mpa | ||
0......7Mpa | 10.5Mpa | ||
Overloadeffect | Negligible | ||
Measuredmedia | Gasesandfluids,alsoaggressiveandcorrosive,asfaras | ||
compatiblewithaluminiumoxideceramics(99.9%) | |||
Materialswettedbyprocess | Diaphragm:99.9%aluminiumoxideceramics(Al2O3) | ||
Powersupply | |||
Supplyvoltage | 5VDCstabilized,minimum4.5V/maximum5.5V | ||
Effectofsupplyvoltage | Onlinearity | Noeffect | |
Onrangestart | Proportional | ||
Onmeasuringrange | Proportional | ||
Ontemperaturecompensation | Noeffect | ||
Max.Supplycurrent | 2mAatavoltagesupplyof4.5V | ||
Typical:<1.5mAatavoltagesupplyof4.5V | |||
Environmentalconditions | |||
Ambienttemperaturerange | -40℃...125℃ | ||
Processtemperaturerange | -40℃...125℃ | ||
Compensatedtemperaturerange | -20℃...80℃ | ||
Storagetemperature | -40℃...125℃ | ||
Thermalchange | |||
Thermalchangeofthelowerrange-valueinthecompensationtemperaturerange:max.±0.75%ofspan, | |||
withextendedspecification±1%ofspan. | |||
Thermalchangeofoutputspaninthecompensationtemperaturerange:max.±0.5%ofspan.Withmeasuring | |||
ranges≤0.4bar±0.8%ofspan,withextendedspecification±1%ofspan. |